UPS comparison chart
Notes: * If V(in) > V(out) then V(out) is unregulated (Vin=vout) If V(in) < V(out) then V(out) is 12V regulated ** Li-Ion chemistry supported with hardware modification, consult manual. |
| Feature |
OpenUPS |
OpenUPS2 |
NUC-UPS |
| Input Voltage |
6-30V |
11-24V |
6-38 |
| Output Voltage |
5-24V (programable) |
12* |
12V |
| Architecture |
Buck/Boost |
Boost |
Buck/Boost |
| Max Power |
6A |
5A |
5A |
| Battery Chemistry |
Li-Ion, Li-Po, LIFEPO4, Lead Acid |
LiFePO4, Li-Ion** |
Li-Ion |
| Battery Charger |
Multiple chemistry charger |
3 state charger |
3 state charger |
| Battery balancing |
Yes |
Yes |
Yes |
| USB Interface |
Yes |
Yes |
Yes |
| SMBUS |
Slave |
Slave |
- |
| Coulomb counting (fuel gauge) |
Yes |
Yes |
Yes |
| Temperature monitoring |
On board |
For each cell |
For each cell |
| Battery design |
External removable |
Onboard removable |
Onboard removable |
| Footprint |
Custom |
2.5" drive footprint |
2.5" drive footprint |
| Windows compatible |
Yes |
Yes |
Yes |
| Linux compatible |
Yes |
Yes |
Linux API planned |
| Motherboard ON/OFF pulse control |
Yes |
Yes |
Yes |
| Deep Sleep power consumption |
<50uA |
1uA |
5uA |
| Availability |
Long life |
Long life |
New product |
|
|